Cavitation at High Flow Rate

E44-1017 · Pump Selection & Cavitation · Pump · ★★

Problem Symptom

High flow, cavitation, loss

Root Cause

[Mechanism] At high flow NPSHr rises with Q squared, so when the pump operates in the high-flow region NPSHr exceeds NPSHa and cavitation occurs.
[Calculation] Rated Q=100m3/h with NPSHr=3.0m; at an actual Q=140m3/h, NPSHr is about 3.0x1.4^2=5.9m while NPSHa stays at 4.2m, a deficit of 1.7m, and the impeller cavitates.
[Design Omission] The working flow was not limited, the NPSHr-Q curve was never checked, and no bypass was provided.

Correct Solution

1) Limit the working flow to <=110% of rated (Q<=110m3/h, open the recirculation valve above that); Q=140% drove NPSHr to 5.9m>NPSHa 4.2m and cavitated, so limiting the flow lowers the required NPSH and removes the cavitation;
2) Check the NPSHr-Q curve and take the high-flow point (at 140% NPSHr=5.9m requires NPSHa>=6.5m); NPSHr rises with Q squared so the check quantifies the margin;
3) Enlarge the inlet to DN200 (h_loss down 0.9m, NPSHa up 0.9m); a large h_loss lowers NPSHa and reducing it raises NPSHa, restoring the margin;
4) Add an inducer at the inlet (lowers NPSHr by about 1.0m); a high required NPSHr causes cavitation and the inducer lowers it, restoring the margin;
5) Carry out a variable-flow cavitation test (measure the critical NPSHr every 10% of flow); without the test the NPSHr-Q relationship is unknown, so measurement validates it and the data fixes the flow limit;
6) Provide a minimum recirculation line (open recirculation below 90% flow to prevent low-load temperature rise); low flow raises temperature and causes cavitation, and recirculation stabilises the pump, preventing low-load cavitation;
7) Select an impeller with a wide high-efficiency zone (flat Q-eta curve); operating off-duty raises the required NPSH and changing the impeller slows the rise, extending life;
8) Write the flow limit and the NPSHr-Q verification into the calculation sheet; the root cause of the high-flow cavitation was a missing Q limit with no NPSHr check, so the calculation sheet closes the loop.

Checklist

References

GB/T 5657-1995 Centrifugal Pumps - General Technical Conditions