E44-1016 · Pump Selection & Cavitation · Pump · ★★
NPSH margin too small, cavitation, noise
[Mechanism] When NPSHa falls below NPSHr the liquid at the pump inlet flashes to vapour and cavitates, eroding the impeller and raising noise sharply.
[Calculation] The original suction-flooded installation height was 5.5m, inlet DN150 at v=1.8m/s, h_loss=1.4m, h_vapour=0.5m, so NPSHa=10.33-5.5-1.4-0.5=2.93m, slightly below NPSHr=3.0m with a margin of -0.07m; impeller life fell from 5a to 1.5a and noise reached 95dB.
[Design Omission] NPSHa was never calculated, no safety margin was allowed for, and no cavitation test was performed.
1) Enlarge the inlet to DN200 (v falls from 1.8 to 1.0m/s, h_loss from 1.4 to 0.5m) and lower the installation height to 3.0m; the original NPSHa=2.93m<3.0m caused cavitation, so NPSHa rises to 6.33m with a 3.3m margin and the cavitation disappears;
2) Verify an NPSH safety margin of >=1.1 x NPSHr (take 3.3m); an insufficient margin causes cavitation and the check secures it, giving quantified acceptance;
3) Add an inducer at the inlet (lowers NPSHr by about 1.0m); a high required NPSHr causes cavitation and the inducer lowers it, restoring the margin;
4) Fit an automatic air vent valve (DN20) at the inlet high point; gas accumulating at a high point lowers NPSHa and the valve removes it, maintaining the margin;
5) Carry out a cavitation test (throttle the inlet down to incipient cavitation and measure the critical NPSHr against the catalogue); without the test the actual NPSHr is unknown, so measurement validates it and the data fixes the margin;
6) Control the duty flow at <=100m3/h of rated flow (excess raises NPSHr); flow above rating causes cavitation and controlling it slows cavitation, protecting the pump in operation;
7) Select a cavitation-resistant impeller (double channel, thickened inlet edge); a standard impeller erodes easily and changing it makes the pump tougher, extending life;
8) Write the NPSH calculation and the priming requirement into the calculation sheet; the root cause of the small margin was a missing NPSHa calculation with no verification, so the calculation sheet closes the loop.
GB/T 5657-1995 Centrifugal Pumps - General Technical Conditions