Eccentric Reducer Installed Reversed at the Pump Inlet

E44-1015 · Pump Selection & Cavitation · Pump Inlet · ★★

Problem Symptom

Reducer installed backwards, gas accumulates, cavitation occurs

Root Cause

[Mechanism] On a horizontal inlet pipe the reducer must be an eccentric reducer installed flat-on-top (flat side up, sloped side down) so that gas is swept along the pipe; installed the other way round (flat side down), gas accumulates at the pump inlet.
[Calculation] With a DN150x100 eccentric reducer installed reversed, an air pocket of about 0.8L forms at the inlet, the gas content rises from 1% to 6%, NPSHa drops from 4.2m to 2.1m - 0.9m below NPSHr=3.0m - and impeller cavitation cuts impeller life from 5a to 1.5a.
[Design Omission] The flat-on-top orientation was never specified, no direction marking was made on the pipe, and the installed orientation was never checked.

Correct Solution

1) Install the eccentric reducer flat-on-top (flat side up, sloped side down); the reversed installation trapped a 0.8L gas pocket and dropped NPSHa to 2.1m<3.0m causing cavitation, so flat-on-top venting brings NPSHa back above 4.2m and removes the cavitation;
2) Mark the flat-on-top direction at the pipe end (red painted arrow plus the word "FLAT ON TOP"); the field installation is easily reversed and the marking prevents the error, giving correct assembly on the first attempt;
3) Give the inlet pipe a 1:50 slope falling toward the pump (elevation difference >=30mm over 1.5m); a reverse slope traps gas while a forward slope drains it, so the line stays gas-free in operation;
4) Fit an automatic air vent valve (DN20, 0.02MPa opening differential) at the high point of the inlet; gas at a high point cannot escape by itself and the valve releases it, providing continuous venting;
5) Verify NPSHa=10.33+Hg-h_loss-h_vapour and keep a margin of >=0.5m (take Hg=-1.0m for flooded suction); a margin missed in the calculation causes cavitation, so the check quantifies acceptance;
6) Carry out a priming start-up test (measure inlet vacuum <= design value and listen for cavitation noise); without the test the installed orientation cannot be known, so measurement validates it and the data fixes the orientation;
7) Control the inlet gas content to <=2% (gas/liquid ratio meter); a high gas content causes cavitation and controlling it slows cavitation, protecting the pump in operation;
8) Write the flat-on-top requirement and the direction marking of the eccentric reducer into the assembly card; the root cause of the reversed installation was a missing orientation marking with no inspection, so the card closes the loop at assembly.

Checklist

References

GB/T 5657-1995 Centrifugal Pumps - General Technical Conditions