E44-1018 · Pump Selection & Cavitation · Suction Line · ★★
Gas accumulation, cavitation, noise
[Mechanism] Gas collects at the high point or in reverse-slope sections of the suction line, forming air pockets that reduce the flow cross-section and cause a local collapse of NPSHa and hence cavitation.
[Calculation] The pipe is 20m long, the two high points each hold a 0.5L pocket with a local gas content of 4%, NPSHa over that section falls from 4.0m to 2.6m<3.0m, and cavitation noise reaches 92dB.
[Design Omission] No venting was provided, no continuous slope was set, and the high points were never checked.
1) Fit automatic air vent valves (DN20, 0.02MPa opening differential, one every 10m) at the high points of the suction line; the 0.5L pockets dropped NPSHa to 2.6m<3.0m and cavitated, and the valves vent the gas, removing the cavitation;
2) Change to a continuous slope toward the pump (1:50, elevation difference >=40mm over 20m); a reverse slope traps gas while a forward slope drains it, so the line stays gas-free in operation;
3) Add a vent port at the highest point of the inlet pipe (manual vent for maintenance); gas at a high point cannot escape by itself and venting clears it, assisting the venting;
4) Verify NPSHa including the gas-content correction (with 4% gas content NPSHa is multiplied by 0.85); gas content lowers NPSHa and the check quantifies it;
5) Carry out a priming and venting test (fill completely before start-up and confirm the vacuum reading is steady); if it is not vented gas occupies the line and cavitates, so venting validates the condition and the data proves the line is clear;
6) Provide gas/liquid separation at the inlet surge drum (0.5m3 volume, 30s residence); incoming gas fluctuates and separation stabilises it, stabilising the inlet;
7) Control the medium gas content to <=2% (deaerate the feed); a high gas content causes cavitation and controlling it slows cavitation, protecting the pump in operation;
8) Write the venting and slope requirements into both the calculation sheet and the assembly card; the root cause of the gas accumulation was a missing vent with a reverse slope, so both documents close the loop.
GB/T 5657-1995 Centrifugal Pumps - General Technical Conditions