Pump Installation Height Exceeds the Permitted Limit

E44-1019 · Pump Selection & Cavitation · Pump · ★★

Problem Symptom

Excessive installation height, cavitation, noise

Root Cause

[Mechanism] A suction-flooded installation height above the permissible value leaves too little NPSHa, so the liquid flashes to vapour and cavitates.
[Calculation] Permissible Hg=4.0m but 5.5m was actually installed, exceeding it by 1.5m; NPSHa=10.33-5.5-1.4-0.5=2.93m<3.0m, cavitation occurred and life fell from 5a to 1.8a.
[Design Omission] Hg was never calculated, NPSHa was never verified, and no installed-machine test was performed.

Correct Solution

1) Lower the installation height to 3.0m (originally 5.5m, the 1.5m excess drove NPSHa to 2.93m<3.0m); a high installation height reduces NPSHa and lowering it raises NPSHa, so NPSHa rises to 4.93m and the cavitation disappears;
2) Verify Hg<=10.33-h_loss-h_vapour-NPSHr-0.5 (take <=3.0m); a missed calculation leads to a high installation and the check quantifies the permissible height;
3) Change to a flooded suction installation (Hg=-1.0m with a tank); suction-flooded installations easily exceed the limit while flooding secures it, keeping NPSHa steady;
4) Enlarge the inlet to DN200 (h_loss from 1.4 down to 0.5m); a large h_loss lowers NPSHa and reducing it raises NPSHa, restoring the margin;
5) Carry out an installation-height verification test (measure the actual NPSHa and compare it with the catalogue NPSHr); without the test the actual height is unknown, so measurement validates it and the data fixes the height;
6) Fit an automatic air vent valve (DN20) at the inlet; gas accumulating at a high point lowers NPSHa and the valve removes it, maintaining the margin;
7) Control the flow at or below rated (excess raises NPSHr); excess raises the required NPSH and cavitates, and controlling it slows cavitation, protecting the pump in operation;
8) Write the installation height and NPSHa into the calculation sheet; the root cause of the excessive height was a missing Hg calculation with no verification, so the calculation sheet closes the loop.

Checklist

References

GB/T 5657-1995 Centrifugal Pumps - General Technical Conditions

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL