E44-1020 · Pump Selection & Cavitation · Double-Suction Pump · ★★
Cavitation biased to one side, noise, erosion
[Mechanism] The two suction passages of a double-suction pump are not equally loaded; on the high-velocity side NPSHr is larger and local cavitation causes biased erosion.
[Calculation] Design assumed equal flow on both sides, but the actual split was 60%/40%; on the high-speed side v=2.4m/s, NPSHr rose from 3.0 to 4.2m, and cavitation eroded that side to a depth of 1.5mm.
[Design Omission] Even flow between the two sides was never verified, the inlet was not made symmetric, and no flow-field test was performed.
1) Change to a symmetric double-suction inlet (bellmouths of equal length on both sides, eccentric reducers evenly distributed); the 60/40 split drove NPSHr to 4.2m on the high-speed side and cavitated it, while symmetry equalises both sides and removes the biased cavitation;
2) Verify the flow difference between the two sides at <=5% (Pitot tube measurement of both side velocities); an unbalanced split raises NPSHr and cavitates, and the check quantifies the balance;
3) Fit a flow straightening grid at the inlet (baffle pitch 80mm); an irregular incoming flow causes the split and the grid equalises it, stabilising the flow;
4) Enlarge the inlet to DN250 (velocity on both sides falls from 2.4 to 1.6m/s); a high velocity raises the required NPSH and reducing it slows the rise, restoring the margin;
5) Carry out a two-sided flow-field test (Pitot tube traverse of the velocity distribution on both sides); without the test the flow split is unknown, so measurement validates it and the data fixes the balance;
6) Add inducer wheels on both inlet sides (lowers NPSHr by about 1.0m); a high required NPSHr causes cavitation and the inducer lowers it, restoring the margin;
7) Control the flow at or below rated (excess aggravates the split); excess worsens the biased cavitation and controlling it slows the effect, protecting against biased erosion in operation;
8) Write the even-flow verification and the two-sided symmetry into the calculation sheet; the root cause of the biased cavitation was a missing even-flow check with a non-symmetric inlet, so the calculation sheet closes the loop.
GB/T 5657-1995 Centrifugal Pumps - General Technical Conditions