E44-1021 · Pump Selection & Cavitation · Pump · ★★
High temperature, cavitation, damage
[Mechanism] A high medium temperature raises the saturation vapour head h_vapour, and NPSHa is offset by more of the available head, so cavitation occurs.
[Calculation] At t=120C h_vapour=1.8m (0.5m for ambient-temperature water), NPSHa=10.33-3.0-1.0-1.8=4.53m against NPSHr=4.0m, a margin of only 0.53m close to incipient cavitation; at t=150C, h_vapour=3.5m and NPSHa=2.83m<4.0m, so the pump cavitates.
[Design Omission] The h_vapour-t relationship was never checked, no cooling was applied, and the inlet pressure was not raised.
1) Cool the medium to t<=100C (pre-cool in a heat exchanger; exceed the limit and adjust); at t=120C the h_vapour=1.8m crowds out NPSHa leaving a margin of only 0.53m, so cooling lowers h_vapour and NPSHa returns to 5.3m, removing the cavitation;
2) Check the h_vapour-t curve and take the working point (at t=120C take h_vapour=1.8m and require NPSHa>=4.5m with a margin of >=0.5m); h_vapour rises with t so the check quantifies the margin;
3) Raise the inlet pressure (pressurising tank, P_inlet+0.3MPa); a high h_vapour lowers NPSHa and raising the pressure compensates, restoring the margin;
4) Change to a heat- and corrosion-resistant pump (duplex steel, usable at t=150C); a high temperature causes cavitation as well as erosion, and changing the pump makes it durable, extending life;
5) Carry out a hot cavitation test (raise t and measure the critical NPSHr); without the test the temperature effect is unknown, so measurement validates it and the data fixes the temperature limit;
6) Add an inducer at the inlet (lowers NPSHr by about 1.0m); a high required NPSHr causes cavitation and the inducer lowers it, restoring the margin;
7) Control t at or below the design value of 100C and interlock a flow reduction on exceedance; overtemperature raises h_vapour and cavitates, and controlling it slows cavitation, protecting the pump in operation;
8) Write the h_vapour-t verification and the cooling requirement into the calculation sheet; the root cause of the high temperature was a missing h_vapour check with no cooling, so the calculation sheet closes the loop.
GB/T 5657-1995 Centrifugal Pumps - General Technical Conditions