Inlet Strainer Clogging Causes Cavitation

E44-1022 · Pump Selection & Cavitation · Inlet Strainer · ★★

Problem Symptom

Strainer clogged, cavitation, noise

Root Cause

[Mechanism] Clogging of the inlet strainer causes a sharp rise in local resistance, the inlet pressure drops, NPSHa becomes insufficient and cavitation occurs.
[Calculation] With a 60-mesh strainer at 50% blockage, DeltaP rises from 0.05 to 0.3MPa, the inlet h_loss increases by 2.5m, and NPSHa falls from 4.5 to 2.0m<3.0m, causing cavitation.
[Design Omission] The strainer was never cleaned, the strainer resistance was never verified, and no differential-pressure alarm was provided.

Correct Solution

1) Clean the inlet strainer and reduce the mesh to 30 mesh (DeltaP falls from 0.3 back to 0.05MPa); 50% blockage raised h_loss by 2.5m and dropped NPSHa to 2.0m<3.0m causing cavitation, while cleaning lowers the resistance so NPSHa returns to 4.5m and the cavitation disappears;
2) Verify the strainer resistance at <=0.05MPa (calculated at v=1.0m/s, K=2.5); a high resistance lowers NPSHa and the check quantifies it;
3) Change to a high-open-area strainer (open area >=70%, originally 50%); a small open area causes blockage and changing it improves the passage, preventing blockage;
4) Provide a strainer differential-pressure alarm (report and clean at DeltaP>0.1MPa); blockage shows up first as a pressure differential, and early reporting leads to cleaning, monitoring the blockage;
5) Carry out a strainer resistance test (measure DeltaP and NPSHa before and after blockage); without the test the effect of blockage is unknown, so measurement validates it and the data fixes the resistance;
6) Add an inducer at the inlet (lowers NPSHr by about 1.0m, leaving margin); a high required NPSHr causes cavitation and the inducer lowers it, restoring the margin;
7) Control the solids content of the medium to <=0.1% (upstream settling); solids cause blockage and controlling them slows it, preventing blockage;
8) Write the strainer cleaning, the resistance verification and the differential-pressure alarm into the specification; the root cause of the cavitation was a missing cleaning routine with no resistance check, so the specification closes the loop.

Checklist

References

GB/T 5657-1995 Centrifugal Pumps - General Technical Conditions