Knowledge Base › Fluid Systems Error Case › Globe Valve Throttling Squeal

Globe Valve Throttling Squeal

E44-849 · Throttling Noise and Vibration · Globe valve · ★★

Problem Description

A DN50 globe valve used for throttling at 10% opening gave an outlet squeal of 90dB(A) and high-frequency stem vibration

Root Cause

[Mechanism] The narrow-gap throttling of a globe valve makes the velocity rise sharply and form a sharp jet noise; a gap only 0.5mm wide produces a high-frequency whistle.
[Calculation] Gap width δ=0.5mm, velocity v=Q/(π·d·δ)=0.005/(3.14×0.05×0.0005)=64m/s, and the squeal band enters the audible high-frequency range.
[Design Omission] No change to a control valve, no silencer, no restriction of the throttling duty.

Corrective Solution

1) Replace with a control valve (use a V-port ball valve or cage valve for throttling), since the original globe valve with a 0.5mm gap at 64m/s squealed, thus replacing the valve cuts the squeal;
2) Verify the sound level (outlet ≤85dB(A)), since exceeding it disturbs and verification meets it, thus verifying sound;
3) Add a silencer (resistive, insertion loss ≥10dB), since the bare valve radiates 90dB(A) and silencing lowers it, thus silencing;
4) Restrict the throttling duty (the globe valve for shutoff only, throttling handled separately), since misuse squeals and restriction stops it, thus restricting use;
5) Monitor the squeal (spectrum analysis of the peak frequency, alarm >85dB(A)), since gradual rise approaches the limit and early detection catches it, thus monitoring the squeal;
6) Run an acoustic test (measure Lw per GB/T3767), since the lack of testing left the squeal undetected and the test reveals the level, thus testing sound;
7) Control the opening to steady it (avoid 10% opening for long periods), since small narrows the gap and squeals and control steadies it, thus controlling the opening;
8) Write the valve replacement and silencing into the specification, since the original lack of replacement is the root cause of squeal and locking it in closes the loop, thus controlling it in the spec.

Checklist

Reference

GB/T 12235-2007 Steel globe valves for petrochemical industry

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL