E44-476 · Filter Clogging and Contamination · Boiler Feedwater Filter 10μm · ★★
Iron oxide deposits in the feedwater plug the screen, Δp=0.2MPa, feedwater flow drops, and the drum level fluctuates
[Mechanism] Fe₃O₄ particles settle on the screen and bridge across.
[Calculation] Particles d=20μm exceed the 10μm screen openings, 50% of openings are jammed, v=Q/A doubles, and Δp=0.2.
[Design Omission] No magnetic removal and no hydrazine reduction, so deposits plugged the screen.
1) Add a magnetic iron remover upstream to remove Fe₃O₄; since 50% of openings jammed, v doubled, and Δp=0.2, removal first keeps feedwater flowing;
2) Add hydrazine to the feedwater line to control oxygen and prevent oxide formation; since oxygen generates iron oxide, oxygen control prevents it;
3) Make the screen backwashable and backwash on schedule; since deposits cause plugging, backwashing cleans it;
4) Add a feedwater Δp alarm; since exceeding it drops flow, the alarm warns;
5) Dose ammonia to the feedwater to adjust pH and prevent corrosion; since corrosion generates iron oxide, pH adjustment prevents it;
6) Cut and inspect tubes periodically for scale; since deposits build gradually, inspection tracks it;
7) Keep a spare filter for rotation; since backwashing interrupts service, rotation avoids shutdown;
8) Write iron removal and oxygen control into the boiler procedure; since iron was never removed, the root cause of fouling, the boiler procedure provides the check.
GB/T 26114-2010 Filters for liquid filtration