E44-475 · Filter Clogging and Contamination · Powder-Conveying Filter 2μm · ★★
Pulse-cleaning pressure was weak at 0.25MPa, powder accumulated on the filter tubes, airflow dropped 30%, and conveying became sluggish
[Mechanism] Cleaning pressure was too low to detach powder from the tube walls.
[Calculation] Detachment requires a reverse Δp > the adhesion force, corresponding to 0.4MPa; the original 0.25MPa broke only 50%, residual resistance rose, and airflow dropped 30%.
[Design Omission] Cleaning pressure was not matched to the adhesion force and the air supply was insufficient, so cleaning was weak.
1) Raise cleaning pressure to 0.5MPa to overcome adhesion; since 0.25MPa broke only 50% and airflow dropped 30%, adequate pressure detaches powder and restores airflow;
2) Enlarge the air receiver to sustain the instantaneous pulse flow; since a small receiver lets pressure drop, a larger volume sustains the flow;
3) Shorten the pulse-jet interval; since powder builds gradually, shorter intervals control it;
4) Add a resistance alarm; since exceeding it drops flow, the alarm warns;
5) Switch to membrane-coated filter tubes for easy release; since bare fabric holds powder, the membrane coating releases it;
6) Inspect air-supply pressure regularly; since a weak supply weakens the jet, supply is checked;
7) Dehumidify at the inlet to prevent powder caking; since moisture causes caking, dehumidification prevents it;
8) Write cleaning pressure into the conveying procedure; since weak pressure was the root cause of buildup, the conveying procedure provides the check.
GB/T 14295-2019 Air filters