E44-474 · Filter Clogging and Contamination · Hydraulic Oil/Water Separation Element · ★★
Water in oil reached 1.5%>0.1%, the water-separation element saturated, downstream valves rusted and jammed, and the oil emulsified
[Mechanism] The coalescing layer absorbed water until saturated and could no longer separate it.
[Calculation] Water capacity M=500mL; cumulative loading reached 800mL beyond capacity, water-separation efficiency dropped from 95% to 40%, and water content reached 1.5%.
[Design Omission] No replacement interval set and no water monitoring, so the element saturated.
1) Set the replacement interval from the water capacity M=500mL; since 800mL exceeded capacity, efficiency fell to 40%, and water reached 1.5%, replacement on schedule restores efficiency;
2) Monitor outlet water content with a water meter for <0.1%; since exceeding it means saturation, water is monitored;
3) Add upstream centrifugal dehydration to reduce the load; since high water loading fills the element, pre-dehydration relieves it;
4) Run two elements in rotation to keep service continuous; since swapping would interrupt flow, rotation avoids shutdown;
5) Vent the tank to prevent condensation ingress; since condensation adds water, venting prevents it;
6) Flush the housing during element changes to remove old water; since residual water re-emulsifies, flushing removes it;
7) Replace as soon as differential pressure rises; since saturation raises Δp, replacement follows Δp;
8) Write the replacement interval into the hydraulic procedure; since no interval was set, the root cause of saturation, the hydraulic procedure provides the check.
GB/T 20080-2014 Hydraulic filter elements