E44-189 · Throttling Noise and Vibration · Process Control Valve · ★★★
Cavitation downstream of the control valve produces 96dB noise and cracks the valve body, with two valves replaced per month
[Cavitation] The Δp drops the downstream pressure below the vapor pressure and forms vapor bubbles.
[Vibration Cracking] The collapse of the bubbles impacts and vibrates the body.
[Design Omission] No staged pressure reduction and no cavitation-resistant valve selection — hence the cracking.
1) Use staged pressure reduction in the control valve to prevent cavitation: because the Δp vaporizes the fluid downstream and the collapsing bubbles vibrate and crack the body, hence staged reduction;
2) Select a cavitation-resistant trim (multi-hole / labyrinth): because bubbles impact, hence cavitation resistance;
3) Keep the pressure-drop ratio ≤0.5 to prevent vaporization: because a large ratio cavitates, hence the ratio limit;
4) Install a silencer downstream to cut the noise: because the noise is 96dB, hence silencing;
5) Damp the support to prevent transmitted vibration: because vibration cracks, hence damping;
6) Choose a thick-walled valve body to resist impact: because collapse impacts, hence thick walls;
7) Measure noise ≤85dB with no cracking at commissioning: the design requirement must be verified by measurement, confirming delivery;
8) Include cavitation resistance in valve selection: the original omission was the root cause of cavitation, so it must be included in selection.
GB/T 17213.1-2015 Industrial-process control valves