E44-190 · Throttling Noise and Vibration · Pump Discharge Check Valve · ★★
Closing the discharge check valve produces water hammer noise of 90dB and pipe vibration
[Hammer Noise] Closing the valve produces a water-hammer Δp surge that generates noise.
[Vibration] The surge is transmitted to the pipe and makes it vibrate.
[Design Omission] Neither slow closure nor silencing was provided — hence the noise.
1) Convert the check valve to slow closing to extend the closing time: because valve closure causes 90dB water hammer and vibration, slow closing clips the peak;
2) Stop the pump softly so the speed falls gradually: because a hard stop causes water hammer, hence the soft stop;
3) Install a water-hammer elimination tank at the discharge: because the peak exceeds the limit, the tank absorbs it;
4) Fit silencing / damping supports on the pipe: because noise and vibration are transmitted, damping suppresses them;
5) Check the flange bolts for pressure rise: because overpressure loosens them, hence the bolt check;
6) Provide a relief valve as a backstop: the peak is hard to predict, so it vents;
7) Measure noise ≤85dB at commissioning: the design requirement must be verified by measurement, confirming delivery;
8) Build slow closure and silencing into the discharge design: the original omission was the root cause of the hammer noise, so it must be included in design.
GB/T 20801-2020 Pressure piping code