E44-914 · Siphon and Backflow · Piping · ★★★
Reflux, material mixing, contamination
[Mechanism] When the pump stops or a valve opens erroneously, two pipelines carrying different materials reflux backward through the shared section and mix.
[Calculation] A differential pressure of 0.15 MPa drives reflux at v≈0.8 m/s, mixing 0.4 m³/h and contaminating the whole section in 1 h.
[Design Omission] No one-way isolation, no differential-pressure check, and no fast shutoff or composition monitoring.
1) Install double check valves ahead of the shared section (in series, each with seepage ≤5 mL/min), because the failure of a single valve requires double insurance and either barrier still isolates, thereby reliably blocking reverse flow;
2) Check the differential pressure between the two streams so the in-use side is ≥ the return side by 0.05 MPa (originally 0.15 MPa lower), because a positive differential pressure eliminates the reverse driving force, thereby preventing reflux by design;
3) Change the return-side valve to pneumatic fast shutoff (≤2 s), because an erroneous opening causes reflux and fast shutoff limits the volume to <0.008 m³, thereby controlling the volume and reducing mixing;
4) Install an online composition analyzer downstream of the shared section (shut off the valve on alarm), because mixing first shows as a composition change before the whole section, thereby intercepting it early;
5) Upgrade the flanges to PN16 with airtightness, because slight leakage causes slow cross-contamination and improved sealing stops the seepage, thereby preventing seepage-driven mixing;
6) Perform a reflux test (open the valve and check the downstream composition for 1 h), because the design omitted the difference check and the test confirms the isolation effect, thereby verifying the isolation;
7) Control the operating differential pressure ≥0.05 MPa with an alarm (adjust if lower), because a stable difference prevents reflux and controlling it prevents mixing, thereby preventing contamination in operation;
8) Write the double check valves and differential-pressure checking into the pipeline regulations, because the root cause of reflux is a reversed difference without isolation, so the regulations must govern to prevent mixing.
GB/T 20801.3-2020 Design code for industrial metallic piping