MOULDLKnowledge Base3D Model DownloadsMembership
中文版Model Store »
Knowledge Base › Fluid System Error Cases › Undersized suction bellmou
HomeModels
Table of contents

Knowledge Base Home

📐 Standard Data

🧮 Calculators

📖 Selection Guides

🏭 Material Grades

❓ Engineer FAQ

🗂 Quick-Reference Categories

❌ Error Case Studies

📚 Technical Articles

Undersized suction bellmouth gives high inlet velocity and cavitation

E44-245 · Pump Selection & Cavitation · Vertical pump 350ZLB-70 · ★★

Problem Symptom

The bellmouth diameter was too small, so the inlet velocity was 2.2m/s (should be ≤1.2m/s); local pressure fell below Pv, cavitation occurred and the inflow was uneven

Root Cause

[Cavitation] An undersized bellmouth raises the inlet velocity and lowers the local pressure below Pv so that cavitation occurs and the inflow becomes uneven.
[Calculation] A small bellmouth area means a high v=Q/A; when v rises from 1.2 to 2.2 the v² term increases 3.4 times, the local pressure drop grows and cavitation follows.
[Design Omission] The bellmouth was not sized for an inlet velocity ≤1.2m/s and was therefore too small.

Correct Solution

1) Enlarge the bellmouth diameter so that the inlet velocity is ≤1.2m/s, because the lower velocity raises the local pressure, thereby eliminating cavitation;
2) Make the bellmouth a streamlined gradual expansion, because a smooth contour reduces the local low pressure, thereby improving the flow pattern;
3) Set the lower edge of the bellmouth at an appropriate height above the tank bottom, because being too close raises the velocity, thereby making the inflow uniform;
4) Fit an anti-vortex plate on the bellmouth, because it prevents vortexing even at low velocity, thereby eliminating entrained air;
5) Check that the inflow distribution at the bellmouth is uniform, because an uneven distribution creates local high velocities, thereby making the inflow uniform;
6) Check the bellmouth velocity at the maximum flow, because the velocity is highest at large Q, thereby covering the worst case;
7) Measure the inlet velocity and pressure during commissioning to confirm compliance, because the design requirement must be verified by measurement, thereby closing out the acceptance;
8) Incorporate the bellmouth sizing into the design standard, because the original undersized bellmouth was the root cause, so the design must include it.

Checklist

References

GB/T 13006-2013 Centrifugal Pumps - NPSH

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL