E44-244 · Pump Selection & Cavitation · Process pump IH80-65-160 · ★★
Air accumulated at a local upward hump in the suction line and formed an air pocket that periodically entered the pump, producing a cyclic flow fluctuation of ±8%
[Cavitation] Air collects at the upward hump of the suction line, the air pocket is released periodically into the pump and intermittent cavitation causes the flow to fluctuate.
[Calculation] The air pocket at the crown of the hump grows with time until it reaches a critical volume and is released into the pump, and the gas slug expands in the low-pressure region and obstructs the flow.
[Design Omission] The suction line had a local upward hump and no venting point, so air accumulated.
1) Change the suction line to a continuously rising or horizontal run with no upward hump, because a hump traps air, thereby letting the gas travel with the liquid;
2) Fit an automatic air vent valve wherever an upward hump is unavoidable, because the high point collects gas, thereby venting it;
3) Slope the suction line with a slight rise toward the pump, because the slope aids venting, thereby eliminating stagnation;
4) Vigorously purge the line before start-up, because residual gas causes the fluctuation, thereby achieving a fully vented line;
5) Install inlet pressure monitoring to detect air pockets, because the pockets cause pressure fluctuation, thereby enabling diagnosis;
6) Avoid sudden changes in suction pipe diameter that trap air, because transitions stagnate the gas, thereby keeping the flow smooth;
7) Verify during commissioning that the flow is stable with no fluctuation, because the design requirement must be verified by measurement, thereby closing out the acceptance;
8) Incorporate the suction line routing and air-trapping prevention into the design, because the original hump was the root cause, so the design must include it.
GB/T 13006-2013 Centrifugal Pumps - NPSH