Loose Packing Gland on the Valve Stem Causes Leakage

E44-1031 · Valve Selection & Internal Leakage · Valve Stem · ★★

Problem Symptom

Loose gland, leakage, dripping

Root Cause

[Mechanism] The packing gland bolts were not tightened to the specified torque, so the preload was insufficient and the medium seeped along the clearance between the packing and the stem.
[Calculation] DN100 gate valve with M16x4 gland bolts needing 90N-m but only 40N-m applied; the actual packing specific pressure was 0.5MPa against the 1.2MPa needed for sealing, with 5 drops/min of leakage.
[Design Omission] The tightening torque was never specified, the packing sealing specific pressure was never verified, and no leakage test was performed.

Correct Solution

1) Tighten the gland bolts diagonally to 90N-m (originally 40N-m); insufficient preload caused the seepage and the full torque restores the seal, stopping the leak;
2) Verify the packing sealing specific pressure at >=1.2MPa (actual 0.5); a low specific pressure leaks and verifying the pressure secures the seal, making it compliant;
3) Change to flexible graphite packing (rebound >=25%, replacing asbestos); the old packing had gone stiff and shrank and leaked, and the new material rebounds, restoring the seal;
4) Inject sealing grease into the micro-gaps; micro-gaps cause dripping and injecting grease closes them, stopping the micro-leakage;
5) Carry out a packing-box leakage test (<=3 drops/min is acceptable); the leak was never verified and measurement confirms the tightness, so the data fixes the seal;
6) Fit a leakage observation window and alarm (report when the drip rate exceeds the limit); seepage shows up first as dripping and early detection gives warning, monitoring the leakage;
7) Control the radial runout of the stem at <=0.05mm in operation (a deviation wears the packing); wobbling wears the packing and controlling the runout protects it, preventing leakage in operation;
8) Write the gland tightening torque into the assembly card; the root cause of the loose gland was a missing torque specification with no specific-pressure check, so the assembly card closes the loop.