Valve Not Fully Open Causes Excessive Loss

E44-1032 · Valve Selection & Internal Leakage · Valve · ★★

Problem Symptom

Not fully open, loss, resistance

Root Cause

[Mechanism] The operating valve was opened only 60% and acted as a throttle, so a high-velocity jet scoured the interior and the local resistance rose sharply with a large pressure loss.
[Calculation] DN200 butterfly valve at 60 degrees (90 degrees is preferred) with v rising from 2.0 to 4.8m/s, local xi=4.5 and local hf=1.1m; the pressure loss after the valve was 18% of the pump head.
[Design Omission] The fully open position was not marked, the opening was never verified, and the pressure loss was never measured.

Correct Solution

1) Open the valve fully to 90 degrees (originally 60 degrees, v falls to 2.0m/s); operating at half open causes large throttling losses and full opening lowers them, reducing the local resistance;
2) Calibrate a mechanical full-open limit stop (90 degrees locked); blind operation gives the wrong position and a calibrated stop makes it certain, so the opening is controllable;
3) Use a control valve for throttling (never throttle with an isolation valve); half-opening an isolation valve causes large losses and using the correct valve type keeps the operation steady, one duty per valve type;
4) Add an opening positioner (4-20mA feedback); a blind position causes the loss and an indicator makes it visible, monitoring the opening;
5) Carry out a resistance test (compare DeltaP fully open and at half open); the loss was never measured and measurement confirms the reduction, so the data fixes the loss;
6) Fit a pressure gauge downstream of the valve (monitor a pressure loss of <=0.1MPa); the loss shows up first as a pressure drop and early detection gives warning, monitoring the loss;
7) Control the opening at fully open in operation (use variable speed instead of throttling for regulation); closing down raises the resistance and controlling the opening keeps it steady, preventing loss in operation;
8) Write the full-open stop position into the specification; the root cause of the loss with the valve not fully open was a missing limit stop with no verification, so the specification closes the loop.

Checklist

References

GB/T 12224-2015 Steel Valves - General Requirements

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »