E44-370 · Water Hammer and Pressure Surge · VFD pump, deceleration too fast · ★★
A VFD deceleration time of only 2s left Δv large, drove Δp=0.9MPa beyond the allowable limit, and leaked at the outlet gasket.
[Mechanism] A 2s deceleration drops v too fast, so the wave is not smoothed.
[Calculation] Δp=0.9 exceeded the allowable limit and caused leakage.
[Design Omission] The deceleration time was not set long enough and the wave was not estimated, so even a VFD suffered hammer.
1) Adjust the VFD deceleration time to ≥15s so Δv is gradual, because 2s left the wave unsmoothed and Δp=0.9 exceeded the limit and leaked; hence slow deceleration reduces the wave;
2) Check the deceleration Δp=ρcΔv with a margin, because the uncalculated value exceeded the limit; hence accurate calculation;
3) Add a slow-closing check at the outlet as dual protection, because a VFD alone still hammers; hence dual protection;
4) Install a surge arrester to cut residual waves, because waves still form; hence peak absorption;
5) Brace the pipe supports against vibration, because the wave transmits; hence pipe bracing;
6) Periodically rehearse the deceleration curve, because drift makes it fast; hence curve rehearsal;
7) Recheck by water-hammer simulation, because estimates fall short; hence simulation;
8) Write the deceleration time into the control logic, because the excessive speed was the root cause of the hammer; hence control discipline.
GB/T 32284-2015 Code for design of pump stations - Water hammer protection