Air ingress through a leaking suction pipe causes cavitation

E44-222 · Pump Selection & Cavitation · Vacuum Suction Pump IH50-32-200 · ★★

Problem Symptom

The flange on the vacuum section of the suction pipe lost its seal and drew in air, so the pump ran with a gas-liquid mixture, the flow dropped 14% and cavitation noise appeared

Root Cause

[Cavitation] The suction side is under vacuum, so any leak point draws outside air in and forms a gas mixture that cavitates.
[Calculation] The suction vacuum of -0.03MPa is below atmospheric pressure, so air leaks inward at the leak point and the slug collapses in the low-pressure zone of the impeller.
[Design Omission] The gaskets and joint reliability of the flanges in the vacuum section were inadequate and no leak detection was provided, so air was drawn in.

Correct Solution

1) Use high-reliability gaskets on the vacuum section flanges and tighten them properly: the vacuum draws in air, so this eliminates the leak points;
2) Reduce the number of flanged joints in the vacuum section: the more joints there are the more leak points there are, so the joints are minimised;
3) Carry out a pressure-holding leak test on the vacuum section: a leak under vacuum is hidden, so this finds the leaks;
4) Apply sealant to threaded connections: threads leak readily, so they are sealed;
5) Fit a vent at the high point of the suction pipe to release residual gas: a gas mixture causes cavitation, so it is released;
6) Install inlet pressure monitoring to identify gas entrainment: a gas mixture causes pressure fluctuation, so this provides a diagnostic;
7) Commission the pump and carry out a vacuum pressure-holding test with no leakage: the design requirement must be verified by measurement, so this confirms the delivery;
8) Include the sealing and leak testing of the vacuum section in the design: the original air ingress was the root cause, so the design must always include it.

Checklist

References

GB/T 13006-2013 Centrifugal Pumps - NPSH