Starting without priming empties the pump and causes dry running

E44-221 · Pump Selection & Cavitation · Centrifugal Pump with Weak Self-Priming IS65-50-160 · ★★★

Problem Symptom

The pump was not primed before start-up, so the trapped air prevented the suction from developing, the impeller ran dry with cavitation and overheating, and the mechanical seal was damaged

Root Cause

[Cavitation] Without priming the pump contains gas, and a centrifugal pump has no self-priming capability, so it empties and runs dry.
[Calculation] The impeller does work on the gas producing a head only about 1/800 of that produced on liquid (the density ratio), so it cannot lift the liquid and the dry running overheats and cavitates.
[Design Omission] There was no priming and venting procedure and no interlock, so the pump ran dry.

Correct Solution

1) Prime the pump thoroughly and vent it before start-up: gas cannot be lifted by a centrifugal pump, so this establishes the suction;
2) Fit a foot valve in the suction pipe to prevent the pipe draining back: the foot valve keeps the pipe full, so priming is not needed every time;
3) Install an automatic priming arrangement (vacuum priming): manual priming is easily forgotten, so this primes automatically;
4) Add a full-liquid interlock to the start-up logic: the pump must not start unless full, so dry running is prevented;
5) Fit dry-run protection to the pump (temperature or current): dry running overheats the machine, so it is stopped in time;
6) Fit a vent valve at the high point to purge the air completely: residual gas causes cavitation, so it must be purged clean;
7) Commission the pump and verify the priming procedure and the interlock operation: the design requirement must be verified by measurement, so this confirms the delivery;
8) Include the priming and venting procedure in the operating instructions: the original failure to prime was the root cause, so the procedure must always include it.

Checklist

References

GB/T 13006-2013 Centrifugal Pumps - NPSH

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL