E44-220 · Pump Selection & Cavitation · Double-Suction Split-Case Pump KQSN300-M9 · ★★★
The inflow to the two suction chambers was asymmetric, so the velocity on one side rose and NPSHr increased, cavitating the impeller on that side with a vibration of 3.8mm/s
[Cavitation] Asymmetric inflow to the double-suction casing sends more flow down one side, raising NPSHr there and causing cavitation.
[Calculation] The asymmetry puts a larger share of the flow through one side, where the velocity rises and NPSHr increases with Q squared, so the NPSHa of that side falls below NPSHr and cavitation occurs.
[Design Omission] The suction pipe layout did not guarantee symmetric inflow to the two halves, so the flow was maldistributed.
1) Arrange the suction pipe symmetrically to ensure even inflow to both sides: with symmetry the flow is equal on both sides and NPSHr is balanced;
2) Leave a sufficient straight run ahead of the pump inlet to stabilise the flow: a straight run homogenises the flow pattern, so the symmetry is obtained;
3) Avoid a side elbow immediately next to the inlet in the suction pipe: a side elbow causes maldistribution, so symmetric inflow is preserved;
4) Fit flow straightening vanes at the inlet to share the flow if necessary: the vanes equalise the flow, so both sides receive their share;
5) Check NPSHr for the worst-case duty on one side: the loaded side is the most tightly constrained, so the worst case is covered;
6) Monitor the vibration to identify maldistribution: maldistribution causes vibration, so this provides a diagnostic;
7) Commission the pump and measure the inlet pressure on both sides to confirm symmetry and no cavitation: the design requirement must be verified by measurement, so this confirms the delivery;
8) Include symmetric inflow to the double-suction casing in the design: the original asymmetry was the root cause, so the design must always include it.
GB/T 13006-2013 Centrifugal Pumps - NPSH