Belt slip lowers the speed and the head, and the fault is wrongly diagnosed as cavitation

E44-223 · Pump Selection & Cavitation · Belt Driven Centrifugal Pump IS100-80-160 · ★★

Problem Symptom

The belt slipped so the actual speed was 2650r/min against a rated 2900, the head fell to 0.84 times the rated value and the flow did not meet the requirement

Root Cause

[Cavitation] A low speed does not itself cavitate, but the head and flow collapse sharply and this is wrongly diagnosed as a cavitation or selection problem.
[Calculation] By the similarity law H varies with n squared; dropping n from 2900 to 2650 (0.914 times) brings H down to 0.835 times and Q, proportional to n, down to 0.914 times.
[Design Omission] The belt drive was not protected against slip and the actual speed was not monitored, so the capability was insufficient.

Correct Solution

1) Tension the belt to eliminate the slip and hold the rated speed: slipping lowers n and H falls with n squared, so this restores the capability;
2) Replace the belt drive with a direct or coupling drive: a direct drive has no slip, so the speed is steady;
3) Install speed monitoring and compare against the rated value: the speed influences the H-Q curve, so this finds the problem in time;
4) Select an anti-slip synchronous belt: a synchronous belt does not slip, so the speed is exact;
5) Re-check the H-Q curve against the actual speed: when n changes the curve shifts, so this gives a true assessment;
6) Establish whether true cavitation is present so the symptom is not confused: a head drop has many causes, so this gives a correct diagnosis;
7) Commission the pump and measure the speed, head and flow against the design values: the design requirement must be verified by measurement, so this confirms the delivery;
8) Include speed monitoring in the design: the original slip going undetected was the root cause, so the design must always include it.

Checklist

References

GB/T 13006-2013 Centrifugal Pumps - NPSH