E44-224 · Pump Selection & Cavitation · Viscous Oil Transfer Pump IS80-65-160 · ★★★
The medium had a viscosity of 320cSt (the pump was selected on water), and after viscosity correction the flow fell 22%, the head fell 18% and the efficiency fell 30%
[Cavitation] The high viscosity was not corrected for, so the flow, head and efficiency decayed badly and this was wrongly attributed to the pump capability or to cavitation.
[Calculation] The viscosity correction factors are CQ=0.78, CH=0.82 and Ceta=0.70; at 320cSt the flow falls 22%, the head falls 18% and the efficiency falls 30%.
[Design Omission] The pump was selected on the water curve with no viscosity correction, so the capability was insufficient.
1) Recalculate and reselect using the viscosity correction factors (CQ, CH and Ceta): viscosity attenuates the capability, so this makes the selection satisfy the duty;
2) Retain a margin for the viscosity attenuation when selecting: the attenuation is large, so the capability is sufficient;
3) Use a positive displacement pump instead of a centrifugal pump for high-viscosity duty: a positive displacement pump is far less affected by viscosity, so the duty is stable;
4) Heat the medium to reduce the viscosity where the conditions allow: warming lowers the viscosity, so this improves the duty;
5) Enlarge the suction pipe diameter to reduce the viscous resistance: viscosity raises hf, so the loss is reduced;
6) Check NPSHr and the inlet conditions at the actual viscosity: viscosity affects cavitation, so the worst case is covered;
7) Commission the pump and measure Q, H and eta with the actual medium: the design requirement must be verified by measurement, so this confirms the delivery;
8) Include the viscosity correction in the selection report: the original omission of the correction was the root cause, so the design must always include it.
GB/T 13006-2013 Centrifugal Pumps - NPSH