Viscosity correction not considered leaves the flow short

E44-224 · Pump Selection & Cavitation · Viscous Oil Transfer Pump IS80-65-160 · ★★★

Problem Symptom

The medium had a viscosity of 320cSt (the pump was selected on water), and after viscosity correction the flow fell 22%, the head fell 18% and the efficiency fell 30%

Root Cause

[Cavitation] The high viscosity was not corrected for, so the flow, head and efficiency decayed badly and this was wrongly attributed to the pump capability or to cavitation.
[Calculation] The viscosity correction factors are CQ=0.78, CH=0.82 and Ceta=0.70; at 320cSt the flow falls 22%, the head falls 18% and the efficiency falls 30%.
[Design Omission] The pump was selected on the water curve with no viscosity correction, so the capability was insufficient.

Correct Solution

1) Recalculate and reselect using the viscosity correction factors (CQ, CH and Ceta): viscosity attenuates the capability, so this makes the selection satisfy the duty;
2) Retain a margin for the viscosity attenuation when selecting: the attenuation is large, so the capability is sufficient;
3) Use a positive displacement pump instead of a centrifugal pump for high-viscosity duty: a positive displacement pump is far less affected by viscosity, so the duty is stable;
4) Heat the medium to reduce the viscosity where the conditions allow: warming lowers the viscosity, so this improves the duty;
5) Enlarge the suction pipe diameter to reduce the viscous resistance: viscosity raises hf, so the loss is reduced;
6) Check NPSHr and the inlet conditions at the actual viscosity: viscosity affects cavitation, so the worst case is covered;
7) Commission the pump and measure Q, H and eta with the actual medium: the design requirement must be verified by measurement, so this confirms the delivery;
8) Include the viscosity correction in the selection report: the original omission of the correction was the root cause, so the design must always include it.

Checklist

References

GB/T 13006-2013 Centrifugal Pumps - NPSH

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL