Suction level too low in the tank causes cavitation

E44-225 · Pump Selection & Cavitation · Tank Transfer Pump IH65-50-160 · ★★★

Problem Symptom

At a low tank level the suction submergence was only 0.3m, so NPSHa fell from 3.5 to 1.8m against NPSHr of 2.4m and cavitation occurred at the low level

Root Cause

[Cavitation] As the tank level falls the suction static pressure drops and at the low level condition NPSHa is insufficient, causing cavitation.
[Calculation] NPSHa=Pa/rho*g+Hz-hf-Pv/rho*g; a 1.5m fall in level drops Hz by 1.5m, so NPSHa falls from 3.5 to 1.8m against NPSHr.
[Design Omission] NPSHa was checked against the average level rather than the minimum level, so cavitation occurred at the low level.

Correct Solution

1) Check NPSHa against the minimum operating level: the low level is the most severe condition, so the worst case is covered;
2) Fit a low-level interlock that stops the pump: at a low level cavitation occurs, so this protects the machine;
3) Raise the suction vessel or lower the pump elevation to increase Hz: the elevation difference raises NPSHa, so this compensates;
4) Fit a low-level alarm in the tank so the condition is handled early: the warning avoids the hazard;
5) Select a pump type with a lower NPSHr to retain a margin: the low level is the tight condition, so the boundary is sufficient;
6) Fit an anti-vortex device at the suction inlet to prevent gas entrainment at a low level: a low level readily forms a vortex, so no gas is carried;
7) Commission the pump at the minimum level and verify there is no cavitation: the design requirement must be verified by measurement, so this confirms the delivery;
8) Include the minimum level check in the design: the original use of the average level was the root cause, so the design must always include it.

Checklist

References

GB/T 13006-2013 Centrifugal Pumps - NPSH