First-stage cavitation on a multistage pump shakes the whole machine

E44-226 · Pump Selection & Cavitation · Multistage Centrifugal Pump D46-50x8 · ★★★

Problem Symptom

The first stage had NPSHa of 2.2m against NPSHr of 2.8m, so first-stage cavitation excited a whole-machine vibration of 4.5mm/s and wore the balance disc

Root Cause

[Cavitation] In a multistage pump the first stage is the suction end, so first-stage cavitation excites the whole machine and unbalances the axial force.
[Calculation] The first stage NPSHa=2.2m against NPSHr of 2.8m; the bubbles collapse in the first-stage impeller and excite vibration that is transmitted to the balance disc.
[Design Omission] The first-stage NPSHr was not checked separately and the margin was insufficient, so cavitation cascaded.

Correct Solution

1) Check the suction conditions separately against the first-stage NPSHr: the first stage on the suction end is the most tightly constrained, so this identifies the critical item;
2) Select a low NPSHr first-stage impeller or fit an inducer: lowering the first-stage NPSHr removes the cavitation;
3) Increase the suction submergence to lift NPSHa: greater submergence raises it, so this compensates;
4) Shorten the suction pipe and reduce its losses: hf consumes NPSHa, so the loss is reduced;
5) Use a cavitation-resistant material for the first stage: cast iron is poor in this respect, so this delays the damage;
6) Monitor the vibration and the balance disc wear: cavitation causes vibration and disc wear, so this provides a diagnostic;
7) Commission the pump and measure the first-stage inlet pressure, confirming no cavitation and no vibration: the design requirement must be verified by measurement, so this confirms the delivery;
8) Include the separate check of the first stage in the design: the original omission of the individual check was the root cause, so the design must always include it.

Checklist

References

GB/T 13006-2013 Centrifugal Pumps - NPSH