Suction lift too great for the self-priming pump, so priming fails

E44-227 · Pump Selection & Cavitation · Self-Priming Centrifugal Pump ZX50-20 · ★★

Problem Symptom

The suction lift was 6.5m against a rating of 5m maximum, the self-priming time exceeded 10min and no water was lifted, with poor gas-liquid separation

Root Cause

[Cavitation] The excessive suction lift demands a vacuum beyond the pump capability and the gas-liquid mixing and separation are poor, so self-priming fails.
[Calculation] The theoretical maximum suction lift is about (Pa-Pv)/rho*g less the margin, about 7m; the actual 6.5m is close to the limit and once the losses are counted no vacuum can be established.
[Design Omission] The suction lift was taken from the theoretical value with no margin and beyond the actual self-priming capability, so priming failed.

Correct Solution

1) Reduce the suction lift to 5m maximum to leave a self-priming margin: a greater lift demands more vacuum, so this makes self-priming reliable;
2) Lower the pump elevation to reduce the suction lift: a lower elevation reduces the lift, so this improves the duty;
3) Use a sufficiently large suction pipe diameter to cut the losses: hf consumes the vacuum, so the loss is reduced;
4) Keep the suction pipe airtight: a leak destroys the vacuum, so the vacuum is preserved;
5) Fill the self-priming chamber on the first start: self-priming needs an initial liquid seal, so this establishes it;
6) Select a pump type with stronger self-priming capability: a larger capability margin makes the duty reliable;
7) Commission the pump and measure the self-priming time and suction lift against the design values: the design requirement must be verified by measurement, so this confirms the delivery;
8) Include the suction lift margin in the selection: the original excessive lift was the root cause, so the design must always include it.

Checklist

References

GB/T 13006-2013 Centrifugal Pumps - NPSH