E44-492 · Filter Blockage and Fouling · Coolant Filter Magnetic Separator · ★★
Magnetic separator catches iron chips but they are not discharged; chips enter the pump with the fluid, impeller worn, flow drops
[Mechanism] Magnetic rods fill up and are not discharged, so chips are carried away.
[Calculation] Rod capacity M=30g is reached, capture rate drops from 95% to 20%, outlet chips at 0.2% damage the pump.
[Design Omission] No scheduled discharge interval and no monitoring; chips are not discharged.
1) Discharge every shift based on rod capacity M=30g, because the original filled rods, 20% capture rate and 0.2% outlet chips damaged the pump, so scheduled discharge restores capture;
2) Monitor magnetic strength and discharge when it drops, because weakened magnets release chips, so magnetic strength is measured;
3) Add downstream fine filtration as a backstop, because chips damage the pump, so a backstop is provided;
4) Add a chip screen upstream of the pump, because chips enter the pump, so chips are screened;
5) Weigh the discharged chips, because declining weight signals deterioration, so weight is logged;
6) Use dual rods rotated for cleaning, because cleaning interrupts flow, so rotation is used;
7) Clean the coolant tank regularly, because buildup grows gradually, so scheduled cleaning is used;
8) Write chip discharge into the coolant specification, because the lack of discharge was the root cause, so the coolant spec governs.
GB/T 17486-2006 Hydraulic filters