Incomplete Air Venting Causing Stick-Slip

E44-675 · Hydraulic System Contamination and Stick-Slip · Air Venting · ★★

Problem Description

Stick-slip, air not fully vented

Root Cause

[Mechanism] Incompletely vented air causes stick-slip.
[Calculation] Air makes the speed uneven and causes crawling.
[Design Omission] No venting, no vent valve, and no inspection were provided, leaving air.

Corrective Solution

1) Add high-point vent valves (automatic venting, every shift); because trapped air in the bore is compressible, making the speed uneven and causing ±1 mm crawling, venting the high points clears the air and prevents crawling;
2) Stroke the cylinder slowly to vent trapped air (3 unloaded strokes at 0.05 m/s); because trapped air vents gradually and slow motion clears it, this removes the air;
3) Keep oil level high to prevent air intake (≥2/3 height, interlock); because low level draws a vortex that sucks in air, controlling the level prevents it and stabilizes the oil;
4) Choose anti-foam oil (defoaming ≤5 min); because foam holds air in the bore and anti-foam oil suppresses it, this reduces air;
5) Monitor crawling (displacement sensor, alarm on shudder >0.3 mm); because crawling progresses invisibly and monitoring detects it, this gives early warning;
6) Seal leaks to prevent air intake (tight fittings plus seals); because internal leakage draws in air and sealing blocks it, this excludes air;
7) Repeat venting (mandatory during commissioning, with records); because incomplete venting causes crawling and repeating it clears the air, this keeps it vented;
8) Write high-point venting into the assembly card (venting sign-off); because the original lack of venting is the root cause of air and assembly fixes it in the procedure, assembly enforces control.