E44-676 · Hydraulic System Contamination and Stick-Slip · Low-Speed Cylinder · ★★
Low-speed crawling, shudder
[Mechanism] Poor low-speed stability causes stick-slip.
[Calculation] Low speed causes crawling.
[Design Omission] No stability upgrade, no cylinder selection, and no adjustment were provided, causing low-speed instability.
1) Select a low-speed stable cylinder (with servo valve, minimum stable speed ≤1 mm/s); because the original low-speed cylinder had friction jumps >30% and speed fluctuation causing crawling, a stable cylinder prevents crawling;
2) Stabilize supply oil pressure (accumulator plus proportional valve, fluctuation ≤0.2 MPa); because instability causes crawling and stabilization stops it, this holds pressure steady;
3) Add venting to exclude air (high-point vent valve); because air intake causes crawling and venting clears it, this excludes air;
4) Adjust seal friction (friction ≤5% of rated, adjust preload); because high friction causes crawling and adjustment reduces it, this lowers friction;
5) Keep speed above the stable threshold (set ≥2 mm/s); because too-low speed causes crawling and keeping above it avoids it, this stabilizes speed;
6) Choose low-friction seals (PTFE composite, μ ≤0.08); because friction causes crawling and low friction suppresses it, this reduces friction;
7) Monitor crawling (laser displacement, alarm on shudder >0.2 mm); because crawling progresses invisibly and monitoring detects it, this gives early warning;
8) Write cylinder and pressure stabilization into the specification (low-speed test); because the original wrong selection is the root cause of the speed issue and fixing it in the specification closes the loop, the design enforces control.
GB/T 23661-2009 Hydraulic cylinders