E44-443 · Two-Phase Flow and Gas Binding · Downstream-of-Valve Bubble Gathering · ★★
Low pressure downstream of the valve releases dissolved gas into slugs, pulsing the downstream flow ±18% and cavitating the pump suction.
[Mechanism] Low pressure downstream of the valve releases gas, which gathers into slugs.
[Calculation] The flow pulses ±18% and gas entering the pump causes cavitation.
[Design Omission] The post-valve pressure was not controlled and no venting was provided — the cause of the downstream gas gathering.
1) Control the post-valve pressure to keep gas in solution and fit venting; low pressure releases slugs, pulses ±18% and cavitates, so control the pressure and vent;
2) Check the post-valve pressure stays above the vapor pressure; low pressure releases gas, so verify the pressure;
3) Keep a stabilizing section after the valve; slugs form just downstream, so stabilize the flow there;
4) Fit a downstream buffer tank to smooth pulsation; it builds up, so buffer it;
5) Keep air out of the pump suction; gas causes cavitation, so prevent it;
6) Fit an inducer to break up the gas; gas binding starves the suction, so use an inducer;
7) Vent periodically; buildup is gradual, so vent and inspect;
8) Write the post-valve pressure into the design; the original slug release was the root cause of pulsation, so gate it at design stage.
GB/T 5657-2013 Technical specifications for centrifugal pumps