Knowledge Base › Fluid Systems Error Case › Backflow Causing the Pump to Run Dry

Backflow Causing the Pump to Run Dry

E44-948 · Siphon and Backflow · Pump · ★★★

Problem Description

Backflow, dry running, damage

Root Cause

[Mechanism] The pump inlet pipe elevation is lower than the upstream liquid level, so after the pump stops the upstream liquid backflows through the inlet and drains the pump casing; on restart there is no liquid to draw in, and the pump runs dry and damages the mechanical seal.
[Calculation] With an inside-outside difference of 1.2 m the backflow is v≈0.5 m/s; 30 min after stopping, the 0.02 m³ pump casing is drained; on restart, 3 s of dry running raises the temperature by 40℃ and burns the mechanical seal.
[Design Omission] No check valve was provided, the elevation difference was not checked, and there was no foot valve to retain the liquid.

Corrective Solution

1) Install a slow-closing check valve at the inlet (seepage ≤5 mL/min), because backflow enters through the inlet and the check valve retains the casing liquid, thereby preventing drainage;
2) Check the inlet elevation so that the pump casing is 0.2 m above the upstream liquid level (originally 1.2 m lower), because a positive difference eliminates backflow and the layout prevents dry running, thereby preventing dry running by elevation;
3) Use a foot valve at the inlet to keep the pump full of liquid (not drained after stopping), because restart needs liquid and the foot valve retains it for suction, thereby preventing dry starting;
4) Provide a level switch in the pump casing interlocked with start-stop (stop when no liquid), because dry running damages the mechanical seal and no liquid stops it, thereby protecting the pump;
5) Perform a backflow test (stop the pump and verify the casing is not empty), because the design omitted the difference check and the test ensures liquid retention, thereby verifying the check valve;
6) Provide a temperature alarm on the mechanical seal (>75℃), because dry running first shows as a temperature rise before burnout, thereby monitoring the temperature for early warning;
7) Control the operating difference ≥0.2 m with an alarm (adjust if lower), because a stable difference prevents backflow and controlling it prevents dry running, thereby preventing dry running in operation;
8) Write the check valve and foot valve into the pump regulations, because the root cause of dry running is a reversed difference without isolation, so the regulations must govern to prevent damage.