Knowledge Base › Fluid Systems Error Case › Air Accumulation in a Siphon Pipe Causing Vibration

Air Accumulation in a Siphon Pipe Causing Vibration

E44-947 · Siphon and Backflow · Siphon Pipe · ★★

Problem Description

Air accumulation, vibration, flow stoppage

Root Cause

[Mechanism] Air trapped in the pipe forms a gas-liquid segment; the unstable flow regime excites vibration in the piping and interrupts the flow.
[Calculation] The air-trapped segment is 1.2 m long, the gas-liquid interface moves at 2.5 Hz, the pipe vibrates 0.25 mm, and the flow drops 45% and stops.
[Design Omission] No venting, no favorable slope, and no air test.

Corrective Solution

1) Install automatic vent valves at the high points (venting on air accumulation, capacity ≥0.5 m³/h), because trapped air is the vibration source and venting suppresses it, thereby removing the source;
2) Change to a favorable slope i≥0.003 (originally adverse), because an adverse slope traps air while a favorable slope lets air drain with the flow, thereby suppressing accumulation;
3) Add a surge tank at the inlet to smooth pulsation (insertion loss ≥10 dB(A)), because pulsation excites vibration and steady flow reduces it, thereby reducing vibration;
4) Raise the flow velocity to 1.3 m/s (originally 0.9 m/s), because air stagnates at low velocity and a higher velocity carries it out, thereby suppressing vibration;
5) Wrap the pipe sections with a damping layer (limit the amplitude to <0.1 mm), because vibration transmits noise and damping suppresses it, thereby suppressing vibration and reducing noise;
6) Perform an air-trapping vibration test (measure the amplitude ≤0.1 mm), because the design omitted venting and the test confirms the vibration level, thereby determining the suppression from data;
7) Monitor the amplitude and flow in operation (alarm if the flow drops >20% or the amplitude exceeds 0.15 mm), because vibration first shows as amplitude before flow stoppage, thereby monitoring the vibration for early warning;
8) Write venting and the favorable slope into the installation card, because the root cause of air trapping is no venting combined with a wrong slope, so installation must govern to prevent vibration and flow stoppage.

Checklist

Reference

GB/T 20801.3-2020 Design code for industrial metallic piping