Knowledge Base › Fluid Systems Error Case › Siphon Height Exceeding the Limit

Siphon Height Exceeding the Limit

E44-949 · Siphon and Backflow · Siphon Pipe · ★★★

Problem Description

Excessive height, loss of suction, break

Root Cause

[Mechanism] The siphon height exceeds the maximum allowable vacuum suction lift, so the pump inlet vacuum is insufficient and the siphon loses suction and stops flowing.
[Calculation] The actual suction lift of 7.5 m exceeds the allowable 6.0 m (atmospheric pressure 10.3 m minus NPSH margin 4.3 m); the inlet vacuum of -78 kPa causes loss of suction and the flow drops to 0.
[Design Omission] The limit was not calculated, the suction height was not checked, and the outlet elevation was not lowered.

Corrective Solution

1) Recalculate the maximum suction lift Hs=Pa/(ρg)-NPSHr-Hf (originally omitted), because 7.5 m exceeds the allowable 6.0 m and a clear calculation makes it controllable, thereby defining the limit;
2) Check the suction height ≤6.0 m (originally 7.5 m), because too high a lift loses suction and checking the height preserves it, thereby bringing the suction height into compliance;
3) Lower the outlet position so that the height difference is ≤6.0 m (lowering by 1.5 m), because too high a lift loses suction and lowering it restores suction, thereby restoring suction by lowering the position;
4) Raise the inlet position or add a booster pump (increasing the inlet pressure by 0.02 MPa), because too low an inlet pressure loses suction and boosting pressure preserves it, thereby making up the pressure;
5) Perform a suction test (verify the flow does not drop), because the design omitted the limit calculation and the test confirms whether suction is lost, thereby determining the suction height from data;
6) Provide a vacuum gauge and alarm at the inlet (<-70 kPa), because loss of suction first shows as low vacuum before flow stoppage, thereby monitoring the vacuum for early warning;
7) Control the operating suction height ≤6.0 m (adjust if exceeded), because a higher suction height loses suction and controlling the height prevents stoppage, thereby preventing loss of suction in operation;
8) Write the limit calculation and height checking into the calculation sheet, because the root cause of lost suction is exceeding the limit without calculation, so the calculation must govern to prevent stoppage.

Checklist

Reference

GB/T 20801.3-2020 Design code for industrial metallic piping