Knowledge Base › Fluid Systems Error Case › Food Sterilization Exchanger Coking

Food Sterilization Exchanger Coking

E44-525 · Heat Exchanger Fouling and Insufficient Heat Transfer · Food Sterilization Exchanger Tube · ★★

Problem Description

Protein coking, K drop, insufficient sterilization temperature

Root Cause

[Mechanism] High-temperature protein cokes onto the wall.
[Calculation] Rf=0.4 cuts K by 35%, leaves sterilization temperature insufficient, a safety risk.
[Design Omission] No wall-temperature control and no CIP, so coking occurs.

Corrective Solution

1) Hold wall temperature below the protein-coking threshold and run CIP; high temperature makes protein coke on the wall (Rf=0.4, K drop 35%, insufficient sterilization temp, safety risk), so temperature control suppresses coking and CIP restores K;
2) Pre-heat feed (raise to near sterilization temperature); cold feed hitting a hot wall suddenly precipitates coke, so pre-heating reduces precipitation;
3) Sterilization-temperature alarm (≥ setpoint); coking leaves temperature insufficient and sterilization incomplete, a risk, so the alarm prevents it;
4) Raise flow velocity to prevent stagnation (≥1.5 m/s); long residence time in low-velocity flow and wall heating promote coking, so higher velocity suppresses it;
5) Change to non-stick material (polished / specialty alloy); coke bonds readily to carbon steel, so a non-stick surface reduces adhesion and eases cleaning;
6) Schedule disassembly cleaning (CIP each batch plus periodic strip-down); once coke hardens CIP cannot remove it, so strip-down cleaning restores the surface;
7) Control concentration to avoid over-concentration; concentrated product cokes readily, so controlling concentration reduces coking;
8) Write temperature control and CIP into the sterilization procedure; the original design omitted wall-temperature control and CIP, the root cause of coking, so the procedure closes the loop.

Checklist

Reference

GB/T 151-2014 Heat exchangers

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL