E44-760 · Uneven Flow Distribution · Multi-Pump Parallel · ★★
Pump flows uneven, one pump over-current, flows biased >15%
[Mechanism] The characteristics of the parallel pumps were not jointly trimmed.
[Calculation] A characteristic difference biases each pump's flow >15%, with the weaker one cavitating and the stronger one over-flowing.
[Design Omission] No joint trimming was done and no characteristic was verified, so the flows were uneven.
1) Jointly adjust each pump's flow (trim the discharge valves to keep the flow difference between pumps ≤5%), because the omitted joint adjustment let identical pumps differ due to piping resistance differences, biasing their flows >15% with the weaker one cavitating and the stronger one over-flowing, thereby splitting the flow evenly by joint adjustment;
2) Verify each pump's characteristic curve (measure the actual Q-H curve and compare), because the unverified characteristics made the selection deviate and the parallel operating point drift, thereby re-matching from the measured data;
3) Provide header pressure stabilization (keep the header pressure fluctuation ≤0.05MPa), because a large pressure difference makes the pumps rob flow and the weaker one stop delivering, thereby evening the load by stabilizing the pressure;
4) Add balance valves (fit one on each branch and adjust until the flows are even), because different branch resistances bias the flow and valve adjustment evens it, thereby balancing the flow;
5) Check the operating condition (monitor each pump's current/flow, alarm above 10% deviation), because gradual bias over-loads one pump until it burns and early detection prevents it, thereby monitoring the deviation;
6) Run a parallel-operation test (open all up, commission jointly, and record each pump's condition), because the omitted test let the bias go unnoticed and the operation ran abnormally, thereby proving even distribution;
7) Control the total flow steady (steady total flow against a single-pump upset), because a total change jumps the parallel operating point and reintroduces the bias, thereby steadying the total;
8) Write the joint adjustment and characteristic verification into the specification, because the omitted adjustment was the root cause of the pump problem and the specification enforces it, keeping the parallel pumps even.
GB/T 13007-2011 Centrifugal pumps