E44-1065 · Heat Exchanger Fouling and Insufficient Heat Transfer · Heat Exchanger · ★★
Thermal-differential crack, leakage, deformation
[Mechanism] A large tube-to-shell temperature difference in the heat exchanger causes differential thermal expansion that generates thermal stress, leading to cracks and leaks at welds / expanded joints.
[Calculation] Δt=120℃, tube-to-shell expansion difference ΔL=αLΔt=12e-6×6000×120=8.6 mm, thermal stress σ=150 MPa exceeds the allowable 120, causing cracking.
[Design Omission] No expansion joint, no thermal-stress verification, and no flexible design were provided.
1) Add a bellows expansion joint (absorbs ΔL=8.6 mm); because differential expansion causes cracking and added flexibility absorbs it, this reduces stress;
2) Verify thermal stress σ≤[σ] (actual 150, exceeds 120); because exceeding allowable causes cracking and stress verification reveals it, this quantifies the problem;
3) Switch to a floating-head design (bundle extends freely); because fixed tubesheet causes cracking and a floating head relieves it, this suppresses stress;
4) Control temperature transients (ramp rate ≤30℃/h); because abrupt temperature changes cause cracking and controlling transients relieves it, this prevents cracking during operation;
5) Perform a hot test (monitor expansion and strain); because cracking was never verified and direct measurement confirms flexibility, this determines stress from data;
6) Install strain gauges + alarm (alarm on overshoot); because cracking first shows up as strain, this monitors cracks and gives early warning;
7) Control the temperature difference in operation to ≤80℃ (adjust on overshoot); because a large temperature difference causes cracking and controlling the difference relieves it, this prevents cracking during operation;
8) Write added flexibility and stress verification into the calculation sheet; because the root cause of thermal-differential cracking is the lack of an expansion joint and stress verification, the calculation enforces control.
GB/T 151-2014 Heat exchangers