E44-594 · Seal Leakage · Globe Valve Seat · ★★
Internal leakage, will not shut off, 0.2L/min flow
[Mechanism] A damaged seat causes the seepage.
[Calculation] The damage prevents tight shut-off and it leaks.
[Design Omission] The seat was never lapped, never inspected and never replaced - the damage was left in place.
1) Lap the seat to a line seal (lapping compound against the disc, continuous contact band); the original damage prevented shut-off and 0.2L/min leaked, and lapping restores the line seal and stops the leak;
2) Change the disc as a matched pair (hard disc or Stellite); damaged seats leak, and changing the disc solves it;
3) Inspect the seat for damage (dye penetrant or visual at every overhaul); damage progresses gradually and then leaks, so the seat is inspected;
4) Select a hard seat (Stellite overlay, HRC >=40); a soft seat is easily damaged, and a hard one prevents that;
5) Control the closing torque (stop as soon as the torque wrench indicates it); excessive torque damages the seat, and controlling it prevents that;
6) Clean the cavity and remove debris (blow through and wipe); debris damages the seat, and cleaning prevents that;
7) Set a routine internal leakage check (pressure hold test); leakage develops gradually, so it is checked;
8) Write the seat lapping and inspection into the maintenance card; the original failure to lap was the root cause of the damage, so the maintenance card closes the loop.
GB/T 12224-2015 Steel Valves