E44-595 · Seal Leakage · Gate Valve Stem · ★★
Stem seal leakage, dripping
[Mechanism] The aged stem seal drips.
[Calculation] The ageing causes the dripping.
[Design Omission] The seal was not replaced, the gland was not tightened and the material was not properly selected - it simply aged.
1) Change the stem seal (flexible packing or a packing box with an isolation ring); the original aged seal dripped, so replacing it stops the dripping;
2) Tighten the gland evenly (diagonal, torqued); a loose gland drips, and tightening it stops that;
3) Polish the stem to Ra0.8 (super-finish); a rough surface drips, and polishing restores the seal line;
4) Select a corrosion-resistant seal (FKM or stainless); corrosion ages the seal, and a resistant material prevents it;
5) Apply sealing grease (compatible grease); a dry seal drips, and greasing prevents it;
6) Check the drip count (every shift, counted); the leak develops gradually into dripping, so the drips are counted;
7) Control the stem runout to <=0.05 (guide sleeve); a wandering stem wears and drips, and controlling the runout prevents that;
8) Write the seal replacement and gland tightening into the maintenance card; the original failure to replace the seal was the root cause of the ageing, so the maintenance card closes the loop.
GB/T 12234-2016 Steel Gate Valves