E44-715 · Hydraulic System Contamination and Crawling · Additive · ★★
Additive failure, property loss
[Mechanism] The additives deplete and the oil loses properties.
[Calculation] Depletion causes property loss.
[Design Omission] No replenishment, no oil change, and no inspection - a design defect leading to depletion.
1) Top up with anti-oxidant and anti-wear additives (2%, ZDP); the depleted additives had cut anti-wear protection and raised wear particles, so replenishment restores the properties;
2) Schedule oil changes to prevent depletion (4000h); oil degrades over time, so changing it renews the properties;
3) Check additive content (spectroscopy; replenish when low); gradual depletion is invisible, so checking makes it measurable;
4) Exclude oxygen to prevent depletion (nitrogen blanketing); oxygen depletes additives, so blanketing slows it and extends service life;
5) Control temperature to prevent property loss (≤55℃); heat depletes additives, so temperature control slows it and extends life;
6) Select stable additives (thermally stable, durable); changing conditions deplete additives, so stable ones keep protection longer;
7) Schedule quarterly oil-quality inspection (additive values); gradual depletion is invisible, so inspection catches it early for early warning;
8) Write additive top-up and oil changes into the maintenance card (additive addition record); since lack of replenishment was the root cause of depletion, closing the loop in the maintenance card gives maintenance control.
GB/T 11118.1-2011 Hydraulic oils