E44-890 · Throttling Noise and Vibration · Valve · ★★
The valve was two sizes smaller than the pipe; throttling turbulence vibrated 0.5mm
[Mechanism] The valve size does not match the pipe, so the velocity changes abruptly and the distorted flow field produces vibration.
[Calculation] The valve v=Q/A is 2.5 times the pipe velocity, and the turbulence vibrates 0.5mm.
[Design Omission] The size was not reselected, the size ratio was not verified, and no support was added.
1) Reselect the size (valve matched to the pipe, size ratio ≤1.5), since the original two-size-smaller valve had 2.5 times the velocity and vibrated 0.5mm, thus proper sizing steadies the flow;
2) Verify the size ratio (valve size/pipe size ≥0.67), since a mismatch vibrates and verification makes it safe, thus checking the ratio;
3) Switch to a full-size valve (a larger valve reduces turbulence), since a mismatch vibrates and replacement fits, thus changing the size;
4) Add supports (brackets at both ends of the valve body), since sway vibrates and support steadies it, thus supporting;
5) Monitor vibration (measure amplitude, alarm >0.2mm), since growing vibration approaches cracking, thus early detection;
6) Run a vibration test (measure the frequency response), since the lack of testing left the vibration undetected and the test reveals the level, thus testing vibration;
7) Control the flow to steady the speed (limit v), since changing conditions cause vibration and steadying controls it, thus controlling speed;
8) Write proper sizing and ratio verification into the specification, since the original lack of sizing is the root cause of the mismatch and locking it in closes the loop, thus controlling it in the spec.
GB/T 12224-2015 Steel valves - General requirements