E44-889 · Throttling Noise and Vibration · Piping system · ★★★
Throttling excited apparent resonance in the piping; the pipe wall vibrated 1.0mm and the weld cracked
[Mechanism] The throttling pulsation frequency coincides with a piping natural frequency, exciting apparent resonance that amplifies vibration and cracks it.
[Calculation] The pulsation frequency f=St·v/d coincides with the piping fn, amplifying amplitude by Q>12.
[Design Omission] No frequency avoidance, no denser supports, no vibration test.
1) Avoid the resonance frequency (change the throttling location or the supports so the pulsation frequency moves off the piping fn by ≥30%), since the near-coincident frequency made the pipe vibrate and crack, thus avoiding the frequency prevents cracking;
2) Verify the natural frequencies (compute each piping fn, detune the layout), since proximity cracks and verification avoids it, thus checking the frequencies;
3) Add denser supports (pipe-clamp spacing ≤3m raises stiffness), since sparse supports vibrate and denser ones suppress it, thus densifying;
4) Add damping (damping layer at the pipe clamps cuts Q), since oscillation vibrates and damping cuts it, thus adding damping;
5) Monitor the vibration (measure the pipe-wall amplitude, alarm >0.3mm), since gradual vibration approaches cracking and early detection catches it, thus monitoring vibration;
6) Run a vibration test (excite and measure the frequency response), since the lack of testing left the vibration undetected and the test reveals the resonance peak, thus testing vibration;
7) Control the flow to steady the speed (limit v), since changing conditions drift the frequency toward resonance and steadying moves it away, thus controlling speed;
8) Write the frequency avoidance and densification into the calculation sheet, since the original lack of avoidance is the root cause of vibration and locking it in closes the loop, thus controlling it in the calculation.
GB/T 11349.1-2006 Mechanical vibration and shock