Knowledge Base › Fluid Systems Error Case › Pipe Support Vibration Transmission

Pipe Support Vibration Transmission

E44-888 · Throttling Noise and Vibration · Support · ★★

Problem Description

Rigid supports transmitted vibration to adjacent equipment, which vibrated 0.4mm

Root Cause

[Mechanism] Rigid pipe supports conduct vibration directly to the building and adjacent equipment.
[Calculation] The rigid transmissibility T≈1; adjacent equipment vibrates 0.4mm.
[Design Omission] No resilient supports, no vibration isolation, no damping.

Corrective Solution

1) Switch to resilient supports (rigid hangers changed to resilient, transmissibility <0.1), since the original rigid T≈1 transmitted 0.4mm vibration to nearby equipment, thus resilient supports isolate it;
2) Verify the natural frequency (support natural frequency kept off the source frequency), since proximity transmits and verification avoids it, thus checking the frequency;
3) Add damping (damping layer in the supports cuts vibration), since oscillation transmits and damping suppresses it, thus adding damping;
4) Avoid the resonance region (adjust the support spacing to leave resonance), since entering it transmits and avoiding it is safe, thus avoiding the region;
5) Monitor vibration (measure adjacent-equipment amplitude, alarm >0.2mm), since growing vibration spreads, thus early detection;
6) Run a vibration test (measure transmissibility), since the lack of testing left transmission undetected and the test reveals the rate, thus testing vibration;
7) Control the flow to steady the speed (limit v to reduce excitation), since changing conditions transmit and steadying controls it, thus controlling speed;
8) Write resilient supports and frequency verification into the assembly card, since the original lack of resilience is the root cause of transmission and locking it in closes the loop, thus controlling it at assembly.

Checklist

Reference

GB/T 11349.1-2006 Mechanical vibration and shock