Knowledge Base › Fluid Systems Error Case › Wrong Silencer Type

Wrong Silencer Type

E44-887 · Throttling Noise and Vibration · Silencer · ★★

Problem Description

A reactive silencer was wrongly chosen; it was ineffective on broadband noise and the outlet stayed at 89dB(A)

Root Cause

[Mechanism] A reactive silencer was wrongly chosen for broadband turbulent noise; the frequency band does not match and the attenuation fails.
[Calculation] Reactive types work on low and mid frequencies; broadband attenuation is <5dB.
[Design Omission] The right type was not chosen, the frequency band was not verified, and no resistive type was fitted.

Corrective Solution

1) Choose the right silencer type (use resistive instead of reactive for broadband), since the reactive type was ineffective on broadband and the level stayed at 89dB(A), thus the right choice cuts the noise;
2) Verify the sound level (≤85dB(A)), since exceeding it is a nuisance and verification confirms compliance, thus checking the sound;
3) Verify the band match (choose the silencer band per the noise spectrum), since a mismatch is ineffective and verification matches it, thus checking the band;
4) Switch to the resistive type (porous absorptive structure), since high frequencies need resistive and switching cuts them, thus changing the type;
5) Monitor the sound (sound-level meter, alarm >85dB(A)), since gradual growth approaches the limit and early detection catches it, thus monitoring sound;
6) Run an acoustic test (measure octave-band sound pressure levels), since the lack of testing left the noise undetected and the test reveals the band, thus testing sound;
7) Control the source to steady the flow (limit Δp), since changing conditions make noise and control steadies it, thus controlling the source;
8) Write the type choice and band verification into the specification, since the original wrong choice is the root cause and locking it in closes the loop, thus controlling it in the spec.

Checklist

Reference

GB/T 3767-2016 Determination of sound power levels of noise sources using sound pressure