E44-891 · Throttling Noise and Vibration · Throttling element · ★★★
After trim wear the clearance grew, noise rose 8dB and performance degraded
[Mechanism] Long-term erosion wears the throttling element; the profile changes, the flow field worsens and noise rises.
[Calculation] Wear grew the throat clearance by 1mm, raising noise by 8dB and degrading the control characteristic.
[Design Omission] No velocity reduction, no hard trim, no wear inspection.
1) Lower the velocity to prevent wear (enlarge the bore so v≤6m/s), since the original erosion grew the throat clearance by 1mm and raised noise 8dB, thus slowing the flow prevents wear;
2) Verify the velocity (≤ critical erosion velocity), since exceeding it wears and verification controls it, thus checking the velocity;
3) Switch to hard trim (tungsten carbide trim), since soft trim wears and replacement resists it, thus switching to hard trim;
4) Raise the back pressure to prevent cavitation (reduce flashing erosion), since low pressure wears and raising it protects, thus raising the pressure;
5) Monitor wear (thickness gauge, alarm >0.5mm), since gradual wear degrades performance, thus early detection;
6) Run a wear test (solids-laden cycling, measure erosion rate), since the lack of testing left wear undetected and the test reveals the rate, thus testing wear;
7) Control the pressure drop by splitting it (single stage Δp≤0.3MPa), since concentration wears and splitting eases it, thus controlling the drop;
8) Write velocity reduction and hard trim into the specification, since the original lack of reduction is the root cause of wear and locking it in closes the loop, thus controlling it in the spec.
GB/T 12224-2015 Steel valves - General requirements