High Oil Temperature and Viscosity Drop Causing Internal Leakage

E44-178 · Hydraulic System Contamination and Stick-Slip · Hydraulic Pump Station · ★★

Problem Description

Oil temperature rose to 75℃ (should be ≤60), viscosity dropped, pump internal leakage increased, volumetric efficiency fell from 92% to 78%

Root Cause

[High Temperature] Oil at 75℃ exceeds the limit and drops the viscosity.
[Internal Leakage] Low viscosity weakens the sealing clearance, raising internal leakage and dropping efficiency.
[Design Omission] No cooling and no temperature control were provided, causing leakage.

Corrective Solution

1) Install an oil cooler to control temperature ≤60℃; because at 75℃ viscosity drops and internal leakage cuts efficiency from 92% to 78%, cooling preserves viscosity;
2) Choose oil that retains viscosity well at high temperature; because viscosity falls with temperature, selecting thermally stable viscosity protects efficiency;
3) Verify pump volumetric efficiency including the temperature drop; because high temperature lowers efficiency, the check accounts for temperature;
4) Size the tank heat-dissipation area adequately; because insufficient dissipation raises temperature, adequate area keeps it down;
5) Monitor oil temperature with alarm; because over-temperature causes leakage, monitoring gives warning;
6) Reduce throttling heat generation in the system; because throttling generates heat, less throttling lowers it;
7) Verify on the test run that oil temperature is ≤60℃ and efficiency meets the design value; because design requirements must be verified by test, this confirms acceptance;
8) Write oil-temperature control into the hydraulic design; because the original lack of cooling is the root cause of high temperature, the design must include it.

Checklist

Reference

GB/T 3766-2015 Hydraulic fluid power - General technical conditions