E44-177 · Hydraulic System Contamination and Stick-Slip · Electro-Hydraulic Servo System · ★★★
Oil at NAS level 12 (should be ≤8), servo spool sticking, actuator shuddering
[Contamination] Particles jam the spool.
[Sticking] A jammed spool loses control and causes shudder.
[Design Omission] No fine filtration and no cleanliness control were provided, causing sticking.
1) Add return-line fine filtration to control cleanliness to NAS ≤8; because oil at NAS 12 contaminates and jams the spool, causing shudder, filtration controls cleanliness;
2) Add magnetic filters in the tank to trap iron swarf; because iron particles damage the valve, magnetic filtration removes them;
3) Filter new oil during filling to prevent bringing in contaminants; because filling itself carries dirt, filtration on filling protects the system;
4) Test oil samples for cleanliness on schedule; because contamination builds up gradually, scheduled inspection catches it;
5) Add an independent fine filter upstream of the servo valve; because the valve is sensitive to particles, upstream filtration protects it;
6) Seal the system against external contamination; because open construction lets in dust, sealing blocks it;
7) Verify on the test run that the valve has no sticking and actuation is stable; because design requirements must be verified by test, this confirms acceptance;
8) Write cleanliness control into the hydraulic design; because the original lack of control is the root cause of contamination, the design must include it.
GB/T 3766-2015 Hydraulic fluid power - General technical conditions