E44-129 · Hydraulic System Contamination and Stick-Slip · Hydraulic Power Unit · ★★
Oil temperature rose to 70℃ (design ≤55℃), viscosity dropped, cylinder speed fluctuated by ±15%
[Temperature Rise] High oil temperature drops the viscosity.
[Calculation] Lower ν changes the throttling characteristics, causing speed instability.
[Design Omission] No cooling was provided, causing instability.
1) Install an oil cooler to control oil temperature ≤55℃; because over-temperature drops viscosity and changes the speed, this stabilizes it;
2) Keep oil temperature within the design range and add temperature control; because a fixed range fixes the characteristics, the speed is stabilized;
3) Choose oil of a suitable viscosity grade (e.g. VG46); because matched viscosity gives stable throttling, the speed is made even;
4) Monitor η and speed trends with warning; because a drop foreshadows instability, this gives early notice;
5) Add both heat-dissipation and temperature-control circuits to the tank; because temperature is controlled, operation is stabilized;
6) Verify and compensate actuator speed for temperature change; because compensation tracks temperature variation, this keeps it accurate;
7) Measure speed fluctuation on the test run (≤±5%); because design requirements must be verified by test, this confirms acceptance;
8) Include heat balance in the hydraulic design; because temperature variation is the root cause, the design enforces prevention of recurrence.
GB/T 3766-2015 Hydraulic fluid power - General technical conditions