E44-128 · Hydraulic System Contamination and Stick-Slip · Hydraulic Cylinder System · ★★
Suction line leaking air, cylinder speed uneven, positioning wavy
[Crawling] Compressible air makes the speed uneven.
[Calculation] A 2% gas fraction lowers stiffness and causes crawling.
[Design Omission] No air-tightness test was performed, causing crawling.
1) Perform an air-tightness test on the suction line and tighten the fittings; because leaks admit air, this seals the joints;
2) Add a high-point vent valve to discharge accumulated gas; because the gas can be vented, this maintains stiffness;
3) Add anti-vortex baffles in the tank to control the oil level; because this prevents cavitation and air entrainment, the oil is kept gas-free;
4) Choose anti-foam oil and add anti-foam additives; because this suppresses foam, entrained air is reduced;
5) Add online gas-fraction monitoring with warning; because exceeding the limit triggers an alarm, this enables early venting;
6) Add negative-pressure protection at the pump inlet; because this prevents cavitation, suction is stabilized;
7) Measure pressure pulsation on the test run (≤±5%); because design requirements must be verified by test, this confirms acceptance;
8) Write air-tightness into the installation specification; because air ingress is the root cause, the specification enforces prevention of recurrence.
GB/T 3766-2015 Hydraulic fluid power - General technical conditions